125 kHz How to Order Guide - D00530, B.7
February 2012 © 2007 - 2012 HID Global Corporation. All rights reserved. Page 21 of 44
FlexPass Formats
The following formats are non-proprietary and are available to all customers. Please call HID to discuss
other formats.
Format Name: 26-BIT WIEGAND
0 to 65,535 (Systems installed prior to June 2003)
0 to 65,535 (All new Systems except FP Lite)
Reader Format Numbers
10022 (1L = 1x Wire for LED control)
10200 (2L = 2x Wires for LED control)
Format Name: 27-BIT INDALA
Card Format Number Facility Code Range ID Number Range
4010X 0 to 8,191 0 to 16,383
Reader Format Numbers
10251 (1L = 1x Wire for LED control)
1026X (2L = 2x Wires for LED control)
Format Name: ABA TRACK 2
Card Format Numbers Facility Code Range ID Number Range
4038X (ASP) 0 to 255 0 to 99,999
17256 (ASP+) 0 to 99,999 0 to 99,999
Reader Format Numbers
11037 OC (Open Collector)
11738 PUR (Pull Up Resistor)
Format Name: RS232 Serial Data
Card Format Number Card Programming Range
16144 up to 24 characters in total length, i.e. ABCD12345678901234567890
Reader Format Number
16144
Format options for FP506B/FP507B Proximity & Keypad Readers (e.g. Format 10022K01)
K01 UnBuffered 8-bit burst */# keys enabled ARK-501
ARK-501 BUFFERED PINKERTON
K07 Buffered Magstripe LSB First 5 digit PIN */# keys enabled
K13 Unbuffered 4 bit burst */# keys enabled
K14 Unbuffered 4 bit burst */# keys disabled